NavList:
A Community Devoted to the Preservation and Practice of Celestial Navigation and Other Methods of Traditional Wayfinding
Re: Another "emergency navigation" sight reduction method
From: Hanno Ix
Date: 2015 Jul 6, 17:40 -0700
The biggest number on your table is 5840. So, there are just 5841 numbers available for the entire table which means the resolution is 1 out of 5841 incl. 0, correct?
N(x) is actually an logarithm of something. Assuming you are always using the same table the absolute value of the entries in a log table are irrelevant - only their ratios matter. So if you where to divide your table by the maximum value - here 5840, actually 0.5440 - then the biggest number would become 1.0000 or, written w/o period, 10000. The other values would grow in the same ratio.
If you continue using just 4 digits again (except for the entry 10000 itself) all of a sudden you get a resolution 1 out of 10000 out of the 4 digits. Therefore, you practically doubled the available resolution and, accordingly, reduced any rounding errors by abt. 50%. This is significant particularly for the very small entries.
I hope I was able to describe this in understandable terms.
From: Hanno Ix
Date: 2015 Jul 6, 17:40 -0700
Stan,
let me repeat an observation and then an idea.If you continue using just 4 digits again (except for the entry 10000 itself) all of a sudden you get a resolution 1 out of 10000 out of the 4 digits. Therefore, you practically doubled the available resolution and, accordingly, reduced any rounding errors by abt. 50%. This is significant particularly for the very small entries.
So, the idea now is doing just that: divide all entries by the biggest entry, and you will exhaust the entire number space available therefore minimizing possible rounding errors. Again, that number space when 4 digits are used is now 0 to 9999 in steps of 1.
D.. Burch could have used with advantage that scaling for his original N(x) .
D.. Burch could have used with advantage that scaling for his original N(x) .
Only if you are concerned about communicating the logarithms per se and not the corresponding natural value to somebody else there would be a problem, and you would also have to communicate the type of scaling you did. This is never a problem when you do SR with the same scaled log table.
BTW: the way such scaling is communicated is by mentioning the base of the logarithm like 2, e, or 10 which are actually being used in technology. Here you don't even have to know that.
I hope I was able to describe this in understandable terms.
H
On Mon, Jul 6, 2015 at 4:06 PM, Stan K <NoReply_StanK@fer3.com> wrote:
FWIW, attached is an N(x) Table with 10' increments, using Hanno's format. It is barely over a half a page as is, but could be made smaller by not having three columns of minutes and by eliminating the 60' lines completely.
StanAttached File: 132099.n(x)-10-90d.xls (no preview available)