Welcome to the NavList Message Boards.

NavList:

A Community Devoted to the Preservation and Practice of Celestial Navigation and Other Methods of Traditional Wayfinding

Compose Your Message

Message:αβγ
Message:abc
Add Images & Files
    Name or NavList Code:
    Email:
       
    Reply
    Re: Centring Error Detector
    From: Brad Morris
    Date: 2014 Jan 23, 17:43 -0500

    Gentlemen

    Please examine the attached rough sketch

    The Ultradex is placed such that the center of rotation is nominally in the center of the FOV of the horizon optical path.  It will disturb the path to the same angle as the index path.  See AA and BB

    In practice then, we would essentially use the sun or moon, and perform the standard index error measurement, albeit at other angles along the arc, say 15°, 30°, 45° etc (this is limited only by the step size of the Ultradex.  For mine, this would be every 1° actual rotation of the Ultradex OR 2° of disturbed path).

    The alignment of the Ultradex is not super critical for the following rational.  We make every effort to insure that at 0°, the index,  we have both paths aligned to perfection, the index error at zero is well established in the community.  After determining the errors all along the arc, *normalize* (arithmetically shift) the curve up or down.  For those more adept arithmetically, the fitted error curve should cross at 0° (the index).  OR since the error just a few degrees away from the index should also be close to zero, just make the actual error curve cross zero there.

    Viola.  Arc (Centering) Error measured and established, without sending your sextant back in time to the Kew Observatory!

    This works because the Ultradex is ultra precise.  The disturbed horizon path is shifted by precise incremental angles, with a precision about 10x our finest sextant resolution.

    Note that this will work for a huge range of angles, as the Ultradex can freely rotate through 360°.  So this will finally permit me to calibrate my Circle of Reflection.

    Comments?  Feedback? 

    Brad

    On Jan 23, 2014 2:32 PM, "Brad Morris" <bradley.r.morris@gmail.com> wrote:

    Correct Örjan.  Its a Hirth radial interface.  From any one position to any other whole degree is accurate (for mine) to 0.5".   The repeatability (for mine) is 1/20".   Mine is divided into 360 parts (degrees).  Its traceable to NIST (National Institute of Standards and Technology) and is calibrated within the last year.  It is a spectacular piece of kit.

    Bill, I've gone through your post.  Yes, the Ultradex can take the place of the SNO-T and make short work of the motion from angle A to angle B.  The motion takes just a few seconds of time (5-10, we want to treat the Ultradex with respect).  In doing so, we have the accuracy and repeatability detailed above.

    I'll make a sketch of the optical path I'm thinking of.  Whilst I do have simultaneous access to a Nikon 6D Autocollimator, I would like to try to replicate the original patent.  There is a fundamental reason.  Last I checked, to purchase the Autocollimator and the Ultradex would cost > $40K.   That puts the solution Örjan specified well out of the reach of many. 

    Patience, the sketch is coming!

    Brad

    On Jan 23, 2014 1:22 PM, "Örjan Sandström" <pokerbacken---.com> wrote:

    Uhm, i think you are both talking what I have been taught is Hirth Rings, accurate to better than 2 arcseconds and repeatable to 0.5 arcseconds.
    A set of 720 tooth rings (two for each indexing platform) should do well as sextant test platform, add a autocollimator and you are set
    should make short work of testing each degree to VERY accurate value, better than the readout of the sextant at any rate.
    ----------------------------------------------------------------
    NavList message boards and member settings: www.fer3.com/NavList
    Members may optionally receive posts by email.
    To cancel email delivery, send a message to NoMail[at]fer3.com
    ----------------------------------------------------------------

    : http://fer3.com/arc/m2.aspx?i=126646

    : http://fer3.com/arc/m2.aspx?i=126648

    File:


       
    Reply
    Browse Files

    Drop Files

    NavList

    What is NavList?

    Get a NavList ID Code

    Name:
    (please, no nicknames or handles)
    Email:
    Do you want to receive all group messages by email?
    Yes No

    A NavList ID Code guarantees your identity in NavList posts and allows faster posting of messages.

    Retrieve a NavList ID Code

    Enter the email address associated with your NavList messages. Your NavList code will be emailed to you immediately.
    Email:

    Email Settings

    NavList ID Code:

    Custom Index

    Subject:
    Author:
    Start date: (yyyymm dd)
    End date: (yyyymm dd)

    Visit this site
    Visit this site
    Visit this site
    Visit this site
    Visit this site
    Visit this site