Welcome to the NavList Message Boards.

NavList:

A Community Devoted to the Preservation and Practice of Celestial Navigation and Other Methods of Traditional Wayfinding

Compose Your Message

Message:αβγ
Message:abc
Add Images & Files
    Name or NavList Code:
    Email:
       
    Reply
    Re: Sextant experiment
    From: Bill B
    Date: 2021 Jun 14, 18:52 +0000

    A few personal observations on IE from Sun's images tangent:

     Frame flex or observer/vision error?

     1.Be sure your eye position is right down the center of the scope for all runs.

     2. Not exactly your experiment but try it with the sextant in standard vertical position, the turn it on its side. I have an astigmatism that causes a circle to be distorted so it is slightly elongated along its vertical axis. Therefore what may appear to be tangent to me is actually not spot on so I get a different IE in both tests.

     Try switching eyes. The astigmatism in my usual shooting eye is mostly vertical. My other eye is primarily horizontal, so my results are different as what I perceive is similar to "sun squish, caused by refraction when the sun is low in the sky.

     As sanity check try viewing a full moon or lighted globe on a clear night with one eye covered then change eyes. Can you discern a difference or distortion? Is so, visit a good optometrist.


    On Sunday, June 13, 2021, 5:31:58 PM EDT, Modris Fersters <noreply_fersters@fer3.com> wrote:


    Hello, Peter! Thank you for your post!

    You wrote:

    How much difference are you seeing?  Can you see it by placing the two solar images in contact, then slowly rolling the sextant 180 degrees (without touching the micrometer assembly)?  A difference of, say, 0.3' or larger would be visible this way

    The difference is dependent on the direction I rotate micrometer. If I rotate it clockwise, then difference is about 0,6 minutes. In this case after rolling sextant by 180 degrees (as you proposed), indeed the two images of the Sun became slightly out of aligment.

    If I rotate micrometer counterclokwise the difference between the IE values is about 0,3 minutes.  

    These differences are caused by movement of the free end of the index arm perpendicular to the plane of the instrument. When sextant is with it face downward and I rotate micrometer clockwise, the friction between worm and rack (plus index arm self weight) favours index arm to move away from frame.

    But these movements are very, very small.

    I disassembled and assembled index bearing following step by step instructions of sextant expert Bill Morris (big thanks to him!). But I could not finde any perceptible movement in the bearing.

    But anyway I am quite satisfied with my sextant SNO-M. Errors of position lines (by artificial horizon) typicaly are 0,05…0,2nm. Only some (the worst) results gives erorrs of 0,28nm (this means that in the worst case the total angle error is 0,56 minutes of arc, because the usage of the AH increases the accuracy twice).

    But I am curious: is this problem typical for sextants. Therefore I proposed this sextant experiment.

    Modris

       
    Reply
    Browse Files

    Drop Files

    NavList

    What is NavList?

    Get a NavList ID Code

    Name:
    (please, no nicknames or handles)
    Email:
    Do you want to receive all group messages by email?
    Yes No

    A NavList ID Code guarantees your identity in NavList posts and allows faster posting of messages.

    Retrieve a NavList ID Code

    Enter the email address associated with your NavList messages. Your NavList code will be emailed to you immediately.
    Email:

    Email Settings

    NavList ID Code:

    Custom Index

    Subject:
    Author:
    Start date: (yyyymm dd)
    End date: (yyyymm dd)

    Visit this site
    Visit this site
    Visit this site
    Visit this site
    Visit this site
    Visit this site